Schneider Conzerv EM6433H / EM6436H / EM6459H

A family of 3-phase digital energy meters that deliver Class 1.0 and Class 0.5 accuracy across all major power parameters. With native RS-485 Modbus RTU communication and a standard 96 × 96 mm DIN form factor, these meters integrate directly with IntelliKran PLCs to bring energy visibility to any crane or industrial panel.

Cl 0.5

Best Accuracy

RS-485

Communication

480 V

Max L-L Input

UL / CE

Certifications

Schneider Conzerv Energy Meter EM6433H EM6436H EM6459H

Features

Complete Energy Visibility in a Standard Panel Format

Full Power Metering

Measures kWh, kVAh, kVARh, kW, kVA, kVAR, voltage (L-N and L-L), current, power factor, and frequency simultaneously across all three phases.

Class 1.0 / 0.5 Accuracy

EM6433H and EM6436H offer Class 1.0 energy accuracy; the EM6459H steps up to Class 0.5 for precision billing and energy audit applications.

RS-485 Modbus RTU

Native RS-485 port connects directly to IntelliKran PLCs and SCADA systems using the industry-standard Modbus RTU protocol. Supports straight-line topology with up to 32 devices per segment.

UL, CE, RCM & EAC Certified

Carries international approvals — UL for North America, CE for Europe, RCM for Australia/New Zealand, and EAC for Eurasian markets — simplifying compliance across regions.

Wide Input Range

Control power accepts 48–277 V AC or DC (±10%), making the meter compatible with virtually all panel supply configurations without an additional power supply.

Compact DIN Panel Mount

Standard 96 × 96 mm front panel footprint fits any IEC 61554 cutout. Minimum side clearance of 28 mm allows meters to be mounted side by side in high-density panels.

Model Variants

Choose the Right Model

ModelTypeAccuracyRS-485Certifications
EM6433HDigital Energy MeterClass 1.0OptionalCE, RCM, EAC
EM6436HDigital Multi-Function MeterClass 1.0StandardUL, CE, RCM, EAC
EM6459HDigital VAF PF MeterClass 0.5StandardUL, CE, RCM, EAC

Measured Parameters

What It Measures

Active energy (kWh) import/export

Reactive energy (kVARh) import/export

Apparent energy (kVAh)

Active power (kW) per phase and total

Reactive power (kVAR) per phase and total

Apparent power (kVA) per phase and total

Power factor per phase and total

Voltage L-N and L-L per phase

Current per phase and neutral

Frequency (Hz)

Demand (kW, kVA)

Voltage and current THD (EM6459H)

Applications

Where It Is Used

Crane motor energy consumption tracking and shift-level reporting

Sub-metering of individual crane panels in multi-crane bays

Energy audit baselines for ISO 50001 compliance programmes

Peak demand monitoring and demand charge reduction

Predictive maintenance via energy pattern analysis

Integration with IntelliKran PLC for unified load + energy data on the web dashboard

Technical Data

Specifications

Model RangeConzerv EM6433H / EM6436H / EM6459H
Accuracy Class (Energy)Class 1.0 (EM6433H, EM6436H) / Class 0.5 (EM6459H)
Voltage InputsV1, V2, V3, VN — up to 277 V L-N / 480 V L-L (CAT III)
Current InputsVia external CTs — I1+/I1−, I2+/I2−, I3+/I3−
Control SupplyAC 48–277 V ±10% / DC 48–277 V ±10%
CommunicationRS-485 Modbus RTU (D1+, D0−)
Recommended RS-485 CableBelden 3105A or 3106A
Termination Resistor120 Ω / 0.5 W (end of line, optional accessory)
Digital I/OD0−, D1+ configurable
Panel Cutout92.0 +0.8 mm × 92.0 +0.8 mm
Overall Dimensions96 mm × 96 mm × 101.5 mm (H × W × D)
Minimum Side Clearance28 mm between adjacent meters
Power System Types5 via display; 13 via ION Setup software
CertificationsUL (EM6436H, EM6459H), CE, RCM, EAC
Wiring (Voltage terminals)0.82–3.31 mm² (18–12 AWG), strip 7 mm, torque 0.9–1.0 N·m
Wiring (CT terminals)2.08–3.31 mm² (14–12 AWG)
Fusing500 mA on L1 (and L2 for ungrounded neutral)

Source: Schneider Electric QSG QGH1336801-02 — Conzerv EM6433H / EM6436H / EM6459H Quick Start Guide.

Safety & Installation Notes

  • Always turn off power before working on the meter or its wiring.
  • Fuse L1 with a 500 mA fuse. Fuse L2 when connecting an ungrounded neutral.
  • Always use grounded external CTs for current inputs.
  • RS-485 supports straight-line topology only — loop or ring topology is not supported.
  • Use Belden 3105A or 3106A shielded cable for RS-485. Terminate end-of-line with a 120 Ω / 0.5 W resistor.
  • Do not exceed 277 V L-N or 480 V L-L (CAT III) at any input terminal.
  • Apply appropriate PPE and follow NFPA 70E or applicable local electrical safety standards.